Dynamics » Hammer Shock Testing (Lightweight)
E-Labs has lightweight hammer shock testing
facilities that test the ability of shipboard installations to
withstand shock loadings. These shock testing facilities are totally
capable of performing MIL-S-901 test requirements.
During lightweight hammer shock testing, an
article is fixed to an anvil plate which is struck by a pendulum
hammer at 1, 3, and 5 foot heights. The anvil plate is struck at
three orientations top, back, and side blows. Testing sequence will
depend on the operating condition that is to be represented.
The E-labs Light Weight Shock Test System has been approved and certified for DoD use by the Department Of The Navy, Naval Surface Warfare Center, Carderock Division, Code 669, for MIL-S-901 High Impact, Light Weight shock testing.
|